● Technical Information:
Planar lightwave circuit (PLC) splitter is a type of optical power management device that is fabricated using silica optical waveguide technology to distribute optical signals from Central Office (CO) to multiple premise locations. Blockless PLC splitter has stronger fiber protection than bare fiber splitter, which is a miniaturization result of cassette splitter. It's mainly used for various connection and distribution boxes or network cabinets.
● Features: |
● Application: |
● Specification:
Table 1 – 1×N PLC Splitter
Parameters |
1×2 |
1×4 |
1×8 |
1×16 |
1×32 |
1×64 |
1×128 |
|
Operating Wavelength (nm) |
1260~1650 |
|||||||
Fiber Type |
SMF-28e G.657A1 or Customer Specified |
|||||||
Insertion Loss (dB)(P/S Grade) |
3.8/4.0 |
7.1/7.3 |
10.2/10.5 |
13.5/13.7 |
16.5/16.9 |
20.5/21.0 |
23.8/24.2 |
|
Loss Uniformity (dB) |
0.4 |
0.6 |
0.8 |
1.2 |
1.5 |
2.0 |
2.5 |
|
Polarization Dependent Loss(dB) |
0.2 |
0.2 |
0.2 |
0.25 |
0.3 |
0.35 |
0.4 |
|
Return Loss (dB)(P/S Grade) |
55/50 |
55/50 |
55/50 |
55/50 |
55/50 |
55/50 |
55/50 |
|
Directivity (dB) |
55 |
55 |
55 |
55 |
55 |
55 |
55 |
|
Wavelength Dependent Loss (dB) |
0.3 |
0.3 |
0.3 |
0.5 |
0.5 |
0.5 |
0.5 |
|
Temperature Stability |
0.4 |
0.4 |
0.4 |
0.5 |
0.5 |
0.5 |
0.5 |
|
Operating Temperature (℃) |
-40~85 |
|||||||
Storage Temperature (℃) |
-40~85 |
|||||||
Device Dimension (mm) |
40×4×4 |
40×4×4 |
40×4×4 |
50×4×4 |
50×7×4 |
60×12×4 |
N/A |
|
Module Dimension (mm) |
100×80×10 |
100×80×10 |
100×80×10 |
120×80×18 |
140×115×18 |
140×115×18 |
140×115×18 |
|
Mini-Module Dimension (mm) |
50×7×4 |
50×7×4 |
50×7×4 |
60×12×4 |
80×20×6 |
100×40×6 |
N/A |
● International Authoritative Certification
Compliance with the international ISO9001, CE, FCC, RoHS standards. FOCC strict implementation of standardized management and control of the design, development, production, installation and service.
● Advantage Details:
(1) High Environmental Stability
► Low insertion loss, low polarization dependent loss, low back reflection, and good uniformity;
(2) Excellent Quality Chips
► Loss of light is not sensitive for wavelength, and it can meet the transmission needs of different wavelengths;
(3) Compact Structure
► Small size, it can be directly installed in a variety of transfer box and just take up little space;
(4) Exquisite Packaging
► The design and packaging is exquisite to ensure the product in good condition.
● Workshop Overviews:
Among the total workshop area of more than 12,000 square meters, dust-free workshop room accupies 500 square meters while dust-proof room occupies 6,500 square meters.
● PLC More Family Products:
Ordering Information:
PLC Splitter
FPS |
Port Configuration |
Input Fiber Type |
Input Fiber Length |
Output Fiber Type |
Output Fiber Length |
Input Connector |
Output Connector |
F=FOCC |
102=1x2 |
B=250um Bare Fiber |
10=1.0m |
B=250um Bare Fiber |
10=1.0m |
0=None |
0=None |
P=PLC |
104=1x4 |
L=900um Loose Tube |
15=5.0m |
R=Ribbon Fiber |
15=5.0m |
1=FC/UPC |
1=FC/UPC |
S=Splitter |
108=1x8 |
T=900um Tight Buffer |
20=2.0mm |
F=Fanout Box With 900um Loose Tube |
20=2.0mm |
2=LC/APC |
2=LC/APC |
|
116=1x16 |
|
|
|
|
3=SC/APC |
3=SC/APC |
........ |
4=SC/PC |
4=SC/PC |
|||||
202=2x2 |
........ |
........ |
|||||
216=2x16 | |||||||
264=2x64 | |||||||
........ |
PLC Splitter Module
FPM |
Port Configuration |
Modules Type |
Cable Type |
Fiber Length |
Input Connector |
Output |
F=FOCC |
102=1x2 |
B=250um Bare Fiber |
09=0.9mm |
10=1.0m |
0=None |
0=None |
P=PLC |
104=1x4 |
L=900um Loose Tube |
20=2.0mm |
15=5.0m |
1=FC/UPC |
1=FC/UPC |
M=Module |
108=1x8 |
T=900um Tight Buffer |
30=3.0mm |
20=2.0mm |
2=LC/APC |
2=LC/APC |
|
116=1x16 |
|
|
|
........ |
3=SC/APC |
........ |
4=SC/PC |
|||||
202=2x2 |
........ |
|||||
216=2x16 | ||||||
264=2x64 | ||||||
........ |